Low PIM Assembly Performance Tracking

Measurement Condition:

  • Electrical:
  • •   Insertion Loss not to exceed
  •     (1.1 x published attenuation + 2 x 0.15dB)
  • •   VSWR
  •     Maximum of 1.25:1 up to 3 GHz
  •     Maximum of 1.35:1 up to 6 GHz
  • PIM: (measured using two +43 dBm carriers)
  • •   IM₃: < -160dBc
  •      (static and dynamic)
  • •   IM₃: SMA's<-155dBc
  •      (static and dynamic)
  • •   IM₃: QMA's<-140dBc (static only)